Description
- Sine wave output 0.1, 0.5 and 0.02 Hz
- Continuously adjustable output voltage
- Continuous duty rating
- Fixed thermal circuit breaker overload
- ‘zero start’ and external interlock provision
- Single-range voltmeter
- Single range current/capacitance meter
- Two-piece portable design
- Transit protected metering
Input: | 120V, 60Hz, 15A peak, 7.5A average or 230V, 50/60Hz, 8A peak, 4A average |
Output: | 0 – 62kVac peak, 0.1/0.05/0.02Hz sinusoidal |
Duty: | Continuous |
Load Rating: | 1.1μF @ 0.1Hz, 2.2μF @ 0.05Hz, & 5.5μF @ 0.02Hz |
Voltmeter: | 3.5″, 0 – 65kVac peak, 2% FS accuracy |
Charging Current meter: | 3.5″, 0 – 100mAac peak 5% FS accuracy |
Load capacitance meter: | 0 – 6μF |
Controls | |
---|---|
Test duration timer: | User programmable |
Cable Lengths: | |
output cable: | 6m Shielded EPR |
Interconnect cable: | 3m |
Size & Weight: | |
Controls: | 660mm w x 330mm d x 406mm h, 34kg |
HV Tank: | 381mm w x 260mm d x 546mm h, 54kg |