PFT-652CM(F) Portable Ac Test Set Dielectric Strength Hipot 0 – 65 kV @ 2 kVA

The PFT-652CM(F) 0 – 65kVac @ 2kVA test set is the latest model to be released by High Voltage, Inc. This highly portable CE Marked two-piece test set provides a continuously adjustable AC voltage typically used to provide a pass/fail AC overvoltage withstand test on low capacitance HV apparatus.

PFT-652CM(F) Brochure

PFT-652CM(F) Portable Ac Test Set Dielectric Strength Hipot 0 – 65 kV @ 2 kVA

Description

The PFT AC Dielectric Test Set Series are AC portable field use hipots. These hipots provide continuously adjustable AC voltage typically used to provide a pass/fail, AC over-voltage withstand test on high voltage apparatus, like switchgear, circuit breakers, reclosers, vacuum bottles, hot sticks, motor windings, bus duct, and any other equipment needing an AC voltage proof test. The PFT Series offers the most field portable, affordable, and easiest to use AC testers at this voltage and power. Higher kVA AC test sets and others designed for motor & generator testing are also available.

 

  • CE Marked. Designed specifically to meet CE directives
  • Continuously adjustable output voltage
  • Fixed overload, factory set to 120% of variable transformer rated output current
  • Zero start and external interlock provision
  • Secondary connected dual-range voltmeter
  • Three-range current meter with guard/ground return circuit
  • Transit protected meters prevent meter damage between test sites

 

Input: 120V, 60Hz, 16A or 230V, 50/60Hz, 8A
Output: 0 – 65kVac, 30mA, 2kVA capacitive load
Duty: 2kVA: 1 hr on, 1 hour off; 1.5kVA continuous

 

Voltmeter: 3.5″, scaled 0-32.5/65kVac, ±2% FS accuracy
Currentmeter: 3.5″, scaled 0-1mAac, ±2% FS with multipliers x1, x10, x100
Guard/ground load return: Yes

 

Controls
Voltage output: Continuously adjustable up to max. voltage
Safety
Interlocks: Zero start and external interface
Protection: Surge and transient

 

Cable Length
Output cable: 1 off, not insulated for HV so must be isolated from ground
Test leads for grounding: 2 off
Interconnect cable: 1 off
Guadred return: RG/58U coax cable
Size & Weight
Controls: 533mm w x 286mm d x 387mm h, 24kg
HV Tank: 305mm w x 330mm d x 343mm h, 23kg

Additional information

Input

120V, 60Hz, 16A or 230V, 50/60Hz, 8A

Output

0 – 65kVac, 30mA, 2kVA capacitive load

Duty

2kVA: 1 hr on, 1 hour off; 1.5kVA continuous

Metering - Voltage measurement

3.5″, scaled 0-32.5/65kVac, ±2% FS accuracy

Metering - Currentmeter

3.5″, scaled 0-1mAac, ±2% FS with multipliers x1, x10, x100

Metering - Guard/ground load return

Yes

Controls - Voltage output

Continuously adjustable up to max. voltage

Safety - Interlocks

Zero start and external interface

Safety - Protection

Surge and transient

Cable Length - Output cable

1 off, not insulated for HV so must be isolated from ground

Cable Length - Test leads for grounding

2 off

Cable Lengths - Interconnect cable

1 off

Cable Length - Guadred return

RG/58U coax cable

Size & Weight - Controls

533mm w x 286mm d x 387mm h, 24Kg

Size & Weight - HV Tank

305mm w x 330mm d x 343mm h, 23Kg