Description
- Sine wave output 0.1, 0.5 and 0.02 Hz
- Continuously adjustable output voltage
- Continuous duty rating
- Fixed thermal circuit breaker overload
- ‘zero start’ and external interlock provision
- Single-range voltmeter
- Single range current/capacitance meter
- Two-piece portable design
- Transit protected metering
Input: | 230V, 50/60Hz, 80A peak |
Output: | 0 – 200kVac peak, 100mA, 0.1/0.05/0.02Hz sinusoidal |
Duty: | Continuous |
Load Rating: | 0.75μF @ 0.1Hz, 1.5μF @ 0.05Hz, 3.75μF @ 0.02Hz |
Cable burning: | Yes |
Voltage: | 3.5″, 0 – 200kVac peak, 2% FS accuracy |
Charging Currentmeter: | 3.5″, 0 – 200mAac peak 5% FS accuracyy |
Load capacitance meter: | 0-6μF |
Controls: | |
---|---|
Data Logger | Automatic |
Test duration timer: | User programmable |
Controls | |
Output cable: | None: bushing output |
Size/Weight: | |
Controls: | 610mm h x 648mm w x 1803mm h, 295kg |
HV Tank: | 1499mm w x 2362mm d x 2210mm h, 1678kg |